  1. EVSE and GFCI PROTECTION - Mike Holt's Forum

    Mar 23, 2024 · The GFCI false trips are vehicle dependent and condition dependent). The protections from an EVSE have the same goal as a NEC GFCI. Anyone wanting a deep dive into EVSE could …

  2. GFCI and "Water Source" | Information by Electrical Professionals for ...

    Mar 15, 2025 · The NEC expanded GFCI protection for dwelling units with basements both finished and unfinished. With considerable urging by manufacturers. -Hal

  3. 2020 GFCI requirements | Information by Electrical Professionals for ...

    Aug 7, 2021 · The requirement for outside GFCI protection at dwelling units requires that the "outlet" have GFCI protection, so it applies to both hard wired and cord and plug connected equipment. I …

  4. GFCI protection dryers | Information by Electrical Professionals for ...

    Jul 23, 2024 · But since its on a GFCI, if the frame provides a decent path back to the panel, that's a separate neutral path and will cause the GFCI to trip. Removing the jumper removes the safety …

  5. Laundry Dryer requires AFCI GFCI protection? | Information by ...

    Aug 13, 2023 · Does a 30 amp dryer outlet require AFCI / GFCI protection? I cannot find a duel function breaker for a double pole square d homeline 30 amp breaker only finding GFCI ones. Solution?

  6. AFCI/GFCI on all breakers - Mike Holt's Forum

    Jul 19, 2025 · GFCI on the other hand, is an old and proven technology that actually saves lives. However, they don’t play well with an ever increasing variety of modern appliances. You may find …

  7. 5mA vs. 30mA sensitivity GFCI breaker | Information by Electrical ...

    Jul 12, 2021 · The 5mA sensitivity GFCI (which is good for personnel protection) was still causing nuisance tripping. Would it be acceptable by NEC to use a 30mA sensitivity (equipment protection) …

  8. Range Tripping GFCI (210.8, 555.53) | Information by Electrical ...

    Aug 9, 2024 · I assume this has been discussed already in this forum but I wasn't able to find a recent thread. NEC 2023 210.8(A)(6) requires all 125-250V single phase receptacles in a kitchen to be …

  9. Length of conductor on GFCI breaker | Information by Electrical ...

    Feb 15, 2013 · I would not install a gfci at the panel on long runs as it will causes problems. Can you install a dead front gfci at the end of the run? What are you wiring?

  10. GFCI 210.8 AFCI changes in 2023 NEC | Information by Electrical ...

    Dec 11, 2022 · The November issue of EC&M has an article on changes in the 2023 NEC. There are a number of changes regarding GFCI protection. The changes are mostly expansion of areas that …